check_snmp_hp-hardware.sh

check_snmp_hp-hardware.sh

  This script requires the HP Insight Management Agents as well as the System Management Homepage application to be installed on each server. Due to the reliance on the Integrated Management Log, you have two options:

  1. Use an SNMP READ+WRITE community setup on the server (BUT NOT USED FOR THIS SCRIPT) so that the System Management Homepage application can be used to clear errors or mark them as repaired to return cpqHeMibCondition.0 to an OK status.
  2. On Windows you may also install the WBEM provider. If you're really cool and your server is running linux, do the following in /etc/snmp/snmpd.conf to make things easy rocommunity rwcommunity 127.0.0.1 see the documentation for HP's System Management Homepage for more information on that application.

Usage:

./check_snmp_hp-hardware.sh snmp community hostname