This plugin checks hardware status for Smart Array Controllers, using the HP Array Configuration Utility CLI. (Array, controller, cache, disk, battery, etc...)

Examples

./check\_cciss -v

RAID OK: Smart Array 6i in Slot 0 array A logicaldrive 1 (67.8 GB, RAID 1+0, OK) (Controller Status: OK Cache Status: OK Battery Status: OK) **./check\_cciss -v -p**
RAID OK:  Smart Array 6i in Slot 0 (Embedded) array A logicaldrive 1 (33.9 GB, RAID 1, OK)
    physicaldrive 2:0 (port 2:id 0 , Parallel SCSI, 36.4 GB, OK)
    physicaldrive 2:1 (port 2:id 1 , Parallel SCSI, 36.4 GB, OK)
    physicaldrive 1:5 (port 1:id 5 , Parallel SCSI, 72.8 GB, OK, spare)
[Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK]

./check\_cciss

RAID OK

Another Examples:

RAID CRITICAL - HP Smart Array Failed: Smart Array 6i in Slot 0 array A (failed) logicaldrive 1 (67.8 GB, 1+0, Interim Recovery Mode)
RAID WARNING - HP Smart Array Rebuilding: Smart Array 6i in Slot 0 array A logicaldrive 1 (67.8 GB, 1+0, Rebuilding)